FLUKE 117

SKU: FLUKE 117

BRAND: Fluke


Fluke 117 Electrician's Digital Multimeter with Non-Contact Voltage

Overview

With its integrated non-contact voltage detection and the AutoV/LoZ function preventing false readings caused by ghost voltage, the Fluke 117 Electrician's Multimeter is the ideal multimeter for electricians. In fact, users around the world have said their 117 is an investment in accuracy. The Fluke 117 provides Min/Max/Average readings, measuring frequency and capacitance. With its easy-to-use design, the Fluke 117 will save you time, allowing you to move from job to job with ease.

Engineered and Tested with Your Safety on the Job in Mind

We test our 117 Multimeters for safe use in CAT III 600 V environments. This is the ideal meter for your electrical work because:

Features

  • VoltAlert™ technology for non-contact voltage detection
  • AutoVolt automatic AC/DC voltage selection
  • Low input impedance: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas
  • True RMS for accurate measurements on non-linear loads
  • Measures 10 A (20 A overload for 30-seconds)
  • Resistance, continuity, frequency and capacitance
  • Min/Max/Average with elapsed time to record signal fluctuations
  • Compact ergonomic design for one-handed operation
  • Compatible with optional magnetic hanger (ToolPak™) for hands free operation
  • CAT III 600 V safety rated

Specification

  • Maximum voltage between any terminal and earth ground : 600 V
  • Surge protection : 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
  • Fuse for A input : 11 A, 1000 V FAST Fuse (Fluke PN 803293)
  • Display Digital: 6,000 counts, updates 4 per second
  • Bar graph : 33 segments, updates 32 per second
  • Operating temperature : -10°C to +50°C
  • Storage temperature : -40°C to +60°C
  • Battery type : 9 volt Alkaline, NEDA 1604A / IEC 6LR61
  • Battery life : 400 hours typical, without backlight
  • Accuracy :
DC millivolts
  • 600mV : (0.1mV) ± (0.5% + 2)
DC volts
  • 6V : (0.001V) ± (0.5% + 2)
  • 60V : (0.01V) ± (0.5% + 2)
  • 600V : (0.1V) ± (0.5% + 2)
Auto volts
  • 600V : (0.1 V) ±(2.0% + 3 (DC, 45 Hz to 500 Hz)) & (4.0% + 3 (500 Hz to 1 kHz))
AC millivolts True RMS
  • 600mV : (0.1mV) ±(1.0% + 3 (DC, 45 Hz to 500 Hz)) & (2.0% + 3 (500 Hz to 1 kHz))
AC volts¹ True RMS
  • 6V : (0.001 V) ± (1.0% + 3 (DC, 45 Hz to 500 Hz)) & (2.0% + 3 (500 Hz to 1 kHz))
  • 60V : (0.01 V) ± (1.0% + 3 (DC, 45 Hz to 500 Hz)) & (2.0% + 3 (500 Hz to 1 kHz))
  • 600V : (0.1 V) ± (1.0% + 3 (DC, 45 Hz to 500 Hz)) & (2.0% + 3 (500 Hz to 1 kHz))
Continuity
  • 600 Ω : (1 Ω) Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
Resistance
  • 600Ω : (0.1Ω) ± (0.9% + 1)
  • 6kΩ : (0.001kΩ) ± (0.9% + 1)
  • 60kΩ : (0.01kΩ) ± (0.9% + 1)
  • 600kΩ : (0.1kΩ) ± (0.9% + 1)
  • 6MΩ : (0.001MΩ) ± (0.9% + 1)
  • 40MΩ : (0.01MΩ) ± (5% + 2)
Diode test
  • 2V : (0.001V) ± (0.9% + 2)
Capacitance
  • 1000nF : (1nF) ± (1.9% + 2)
  • 10μF : (0.01μF) ± (1.9% + 2)
  • 100μF : (0.1μF) ± (1.9% + 2)
  • 9999μF : (1μF) ± (1.9% + 2)
  • 100μF to 1000μF : ± (1.9% + 2)
  • > 1000μF : (0.01MΩ) ± (5% + 2)
Low Impedance Capacitance
  • 1nF to 500μF : (10% + 2 typical)
AC amps True RMS (45 Hz to 500 Hz)
  • 6A : (0.1A) 1.5% + 3
  • 10A : (0.01A) 1.5% + 3
  • 20A continuous overload for 30 seconds max
DC amps
  • 6.000A : (0.1) 1.0% + 3
  • 10.00A : (0.01A) 1.0% + 3
  • 20 A continuous overload for 30 seconds max
Hz (V or A input)
  • 99.99 Hz : (0.01 Hz) 0.1% + 2
  • 999.99 Hz : (0.1 Hz) 0.1% + 2
  • 9.999 Hz : (0.001 Hz) 0.1% + 2
  • 50.00 Hz : (0.01 Hz) 0.1% + 2