CRL 12-01036

SKU: CRL 12-01036

BRAND: Clearline


Clearline Tripconnect 1P multi-fuction Protective device, designed to measure single phase two wire AC active energy and used in over & under voltage protection as well as over current protection

Tripconnect 1P Multi-fuction Protective Device

Overview

The Tripconnect 1P multi-fuction Protective device is designed to measure single phase two wire AC active energy and used in over & under voltage protection as well as over current protection. In case of over/under voltage or over current fault in line, this product can instantly power off the load to prevent electrical equipment from being damaged. The over & under voltage and over current values of this product can all be set up by oneself and can be adjusted on the basis of local practical condition. The product has a long use of life with the advantageof high stability,high over load capability, low power loss and wide working voltage.

Features

  • Over current protection, over voltage protection, under voltage protection can disable one , two or three of them.
  • Voltage and Current Accuracy 0.5%
  • It’s own power consumption <0.5W
  • Can be manually and automatically reconnect.
  • Can set the delay on and delay off time.
  • Can be used as a normal switch.
  • Can be used as a cycle switch. Remarks The product does not have a battery. If the external power supply is out of
  • power, the cycle time starts from 0.
  • Electricity metering accuracy Class 1.
  • Backlight mode is optional, convenient for user scene selection.
  • Malignant load identification limit (pure resistive load), for apartments Rental housing restrictions Fast heat
  • Electromagnetic Kettle Electric rice cooker and other resistive high-power equipment.

Specifications

  • Input working voltage : 85~300V
  • Overvoltage protection value : 85~300V (default 180V)
  • Under voltage protection value : 1-80A (default 60A)
  • Over current protection value : 1-80A (default 60A)
  • Rated frequency : 50/60Hz
  • delay in switch on after power off : 2-255s (default 10s)
  • Voltage circuit power consumtion : 1W
  • Current circuit power consumption : <1VA
  • Active energy display range : 0~9999.9kWh
  • Voltage/current/active power accurate : ±0.5%
  • Active energy accurate : ±1% (IEC62053-21)
  • Operating temperature : -25°C to +70°C
  • Storage temperature : -40°C to +80°C
  • Relative humidity : 85%
  • Altitude : 2500m
  • Electromagnetic Enviroment : E2
  • Mechanical life : 100000 cycles
  • Dimensions : 100 X 36 x 67mm

Downloads

Additional Information

Device Protective Device
Type Tripconnect | 1P | Multi-fuction