{"product_id":"fluke-378fc","title":"FLUKE 378FC","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eDigital Clamp Meter Non-Contact Voltage True RMS 1000V AC\/DC with IFLEX, Max Resistance:60kΩ, Max Jaw Opening:34mm, CAT III 1000V, CATIV 600V\u003c\/span\u003e\u003c\/div\u003e\u003ch1\u003eNon-Contact Voltage Digital Clamp Meter\u003c\/h1\u003e\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv\u003e\u003cul\u003e\r\n\u003cli\u003eMeasure voltage and current with your clamp jaw\u003c\/li\u003e\r\n\u003cli\u003eFaster, safer testing – all without touching a live wire – using FieldSense™ technology\u003c\/li\u003e\r\n\u003cli\u003ePower quality indicator shows whether equipment or power line is faulty\u003c\/li\u003e\r\n\u003cli\u003eComplete 3-phase voltage and current tests in 3 quick steps\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"3\"\u003e\r\n\u003cp\u003eGeneral specifications\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\"\u003e\r\n\u003cp\u003eGeneral Maximum Voltage between any Terminal and Earth Ground\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e1000 V\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003e\r\n\u003cp\u003eBattery\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eType\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e2 AA IEC LR6 alkaline\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eLife\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e200 hour\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\"\u003e\r\n\u003cp\u003eDisplay\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eDual readout\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\"\u003e\r\n\u003cp\u003eAutomatic Power Off\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e20 minutes\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003eElectrical\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003eAC Current: Jaw\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eRange\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e999.9 A\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eResolution\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e0.1 A\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eAccuracy\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e2 % ±5 digits (45 Hz to 66 Hz)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eCrest Factor (50\/60 Hz)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e3 @ 500 A\u003cbr\u003e 2.5 @ 600 A\u003cbr\u003e 1.42 @ 1000 A\u003cbr\u003e Add 2 % for C.F. \u0026gt;2\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003eAC Current: Flexible Current Probe\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eRange\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e2500 A\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eResolution\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e1 A (≤2500 A) 0.1 A (≤999.9 A)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eAccuracy\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e3 % ±5 digits (5 Hz to 500 Hz)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eCrest Factor (50\/60Hz)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e3.0 at 1100 A\u003cbr\u003e 2.5 at 1400 A\u003cbr\u003e 1.42 at 2500 A\u003cbr\u003e Add 2 % for C.F. \u0026gt;2\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003ePosition Sensitivity\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"4\"\u003e \u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eDistance from Optimum\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003ei2500-10 Flex\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003ei2500-18 Flex\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eError\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eA\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e0.5 in (12.7 mm)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e1.4 in (35.6 mm)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e± 0.5 %\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eB\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e0.8 in (20.3 mm)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e2.0 in (50.8 mm)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e± 1.0 %\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eC\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e1.4 in (35.6 mm)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e2.5 in (63.5 mm)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e± 2.0 %\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003eMeasurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003eDC Current\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eRange\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e999.9 A\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eResolution\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e0.1 A\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eAccuracy\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e2 % ±10 digits\u003csup\u003e1\u003c\/sup\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003e\u003csup\u003e[1]\u003c\/sup\u003eWhen using the ZERO function to compensate for offsets\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003eAC Voltage: Field Sense\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eRange\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e1000 V\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eResolution\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e1 V (≤1000V)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003e\r\n\u003cp\u003eAccuracy\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e≤4\/0 AWG\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"3\"\u003e\r\n\u003cp\u003e3 % ±5 digits (45 Hz to 66 Hz)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e≥4\/0 AWG\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"3\"\u003e\r\n\u003cp\u003e5 % ±5 digits (45 Hz to 66 Hz)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003ePosition wire as close as possible to jaw opening (see illustration).\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003eAC Voltage: Test Leads\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eRange\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e600.0 V 1000 V\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eResolution\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e0.1 V (≤600.0 V)\u003cbr\u003e 1 V (≤1000 V)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eAccuracy\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e1 % ±5 digits (20 Hz to 500 Hz)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003eDC Voltage\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eRange\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e600.0 V\u003cbr\u003e 1000 V\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eResolution\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e0.1 V (≤600.0 V)\u003cbr\u003e 1 V (≤1000 V)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eAccuracy\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e1 % ±10 digits\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003emV dc\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eRange\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e500.0 mV\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eResolution\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e0.1 mV\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eAccuracy\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e1 % ±5 digits\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003eAmps Frequency: Jaw\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eRange\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e45 Hz to 66 Hz\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eResolution\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e0.1 Hz\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eAccuracy\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e0.5 % ±5 digits\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eTrigger Level\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e5 Hz to 10 Hz, ≥10 A\u003cbr\u003e 10 Hz to 100 Hz, ≥ 5 A\u003cbr\u003e 100 Hz to 500 Hz, ≥ 10 A\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003eAmps Frequency: Flexible Current Probe\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eRange\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e5.0 Hz to 500.0 Hz\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eResolution\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e0.1 Hz\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eAccuracy\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e0.5 % ±5 digits\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eTrigger Level\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e5 Hz to 20 Hz, ≥25 A\u003cbr\u003e 20 Hz to 100 Hz, ≥20 A\u003cbr\u003e 100 Hz to 500 Hz,≥25 A\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003eResistance\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eRange\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e60.00 kΩ\u003cbr\u003e 6000 Ω\u003cbr\u003e 600.0 Ω\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eResolution\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e0.1 Ω (≤600.0 Ω)\u003cbr\u003e 1 Ω (≤6000 Ω)\u003cbr\u003e 10 Ω (≤60.00 kΩ)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eAccuracy\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e1 % ±5 digits\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003eCapacitance\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eRange\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e1000 μF\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eResolution\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e0.1 μF (≤100.0 μF)\u003cbr\u003e 1 μF (≤1000 μF)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eAccuracy\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e1 % ±4 digits\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003eMechanical\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eSize (L x W x H)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e274 mm x 86 mm x 47 mm\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eWeight (with Batteries)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e463 g\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eJaw Opening\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e34 mm\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eFlexible Current Probe Diameter\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e7.5 mm\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eFlexible Current Probe Cable Length (head to electronics connector)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e1.8 m\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eRogowski Coil Length\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e450 mm\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003eEnvironmental\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eOperating Temperature\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e-10 °C to 50 °C\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eStorage Temperature\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e-40 °C to 60 °C\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eOperating Humidity (without condensation)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003eNon condensing (\u0026lt;10 °C)\u003cbr\u003e ≤90 % RH (10 °C to 30 °C)\u003cbr\u003e ≤75 % RH (30 °C to 40 °C)\u003cbr\u003e ≤45 % RH (40 °C to 50 °C)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eTemperature Coefficients\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003eAdd 0.1 x specified accuracy for each degree C \u0026gt;28 °C or \u0026lt;18 °C\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eIngress Protection\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003eIEC 60529: IP30 (jaw closed)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eOperating Altitude\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e2000 m\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eStorage Altitude\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e12 000 m\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"6\"\u003e\r\n\u003cp\u003eElectromagnetic Compatibility (EMC)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eInternational\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"3\"\u003e\r\n\u003cp\u003eIEC 61326-1: Portable Electromagnetic Environment\u003cbr\u003e IEC 61326-2-2, CISPR 11: Group 1, Class B\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e\u003cem\u003eGroup 1: Equipment has intentionally generated and\/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.\u003c\/em\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e\u003cem\u003eClass B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes.\u003c\/em\u003e\u003cbr\u003e \u003cem\u003eEmissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.\u003c\/em\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eKorea (KCC)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"3\"\u003e\r\n\u003cp\u003eClass A equipment (Industrial Broadcast \u0026amp; Communications Equipment)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e\u003cem\u003eClass A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.\u003c\/em\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eUSA (FCC)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003eSafety\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eGeneral\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003eIEC 61010-1: Pollution degree 2\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eMeasurement\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003eIEC 61010-2-032: CAT III 1000 V \/ CAT IV 600 V\u003cbr\u003e IEC 61010-2-033: CAT III 1000 V \/ CAT IV 600 V\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eCurrent Clamp for Leakage Current Measurements\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003eIEC 61557-13: Class 2, ≤30 A\/m\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003e\r\n\u003cp\u003eWireless Radio\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eRadio Frequency Certification\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003eFCC ID: T68-FBLE IC:6627A-FBLE\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eFrequency Range\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e2405 MHz to 2480 MHz\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eOutput Power\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e\u0026lt;100 mW\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eRadio Frequency Data\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\r\n\u003cp\u003e\u003ca href=\"https:\/\/media.fluke.com\/800638fd-35f1-402a-9b65-b10800e062bb_original%20file.pdf\"\u003eRadio Frequency Data For Class A Devices\u003c\/a\u003e\u003cbr\u003e SIMPLIFIED EU DECLARATION OF CONFORMITY\u003cbr\u003e Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014\/53\/EU. The full text of the EU declaration is available at the following internet address: \u003ca href=\"https:\/\/media.fluke.com\/ef664f31-68ef-40d9-9ca7-b10800bf192b_original%20file.pdf\"\u003ehttps:\/\/media.fluke.com\/ef664f31-68ef-40d9-9ca7-b10800bf192b_original%20file.pdf\u003c\/a\u003e.\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\u003col\u003e\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D1590197932.pdf\"\u003eDatasheet - FLUKE 378FC\u003c\/a\u003e\u003c\/li\u003e\u003c\/ol\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\" cellpadding=\"7\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eClamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":53705816080684,"sku":"FLUKE 378FC","price":20335.0,"currency_code":"ZAR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0075\/8228\/5897\/files\/583493ed4d6900d8817f22efe36406e5.jpg?v=1786663183","url":"https:\/\/www.communica.co.za\/products\/fluke-378fc","provider":"Communica South Africa","version":"1.0","type":"link"}