{"product_id":"ssa3032x-r","title":"SSA3032X-R","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eSIGLENT Spectrum Analyzer 9kHZ~3.2GHz, TFT LCD Multi-Touch Screen 10.1INCH, Resolution Bandwidth:1Hz~3MHz, Phase Noise:\u0026lt;-98 dBc\/Hz, Total Amplitude Acc:\u0026lt; 0.7dB, DANL:-165dBm\/Hz, up to 40MHz Real-Time Analysis Bandwidth, 393×207×116.5mm, 4.7kg\u003c\/span\u003e\u003c\/div\u003e\u003ch1\u003e9kHZ~3.2GHz  Spectrum Analyzer\u003c\/h1\u003e\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cdiv\u003e\u003cp\u003eThe SIGLENT SSA3000X-R real-time spectrum analyzers are powerful and flexible tools for complex RF spectrum, signal analysis and network analysis. With a capability of 40 MHz analysis bandwidth and 7.2 µs 100% POI, the analyzer can provide multi-dimensions data displays, advanced triggering, and RF data capturing, to solve modern RF spectrum challenges, like hopping frequency, conflict channel, spectrum interference, and analog\/digital modulation analysis, EMI pre-compliance test. They also provide a 1-path-2-port vector network analyzer and a distance-to-fault locator for S-parameter measurement, cable and antenna testing. Applications include broadcast monitoring\/evaluation, cellular site, IoT, Wlan and Bluetooth, surveying, research and development, education, production, and maintenance. \u003c\/p\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv\u003e\u003cul\u003e\r\n\u003cli\u003e\u003cspan class=\"fontstyle0\"\u003eSpectrum Analyzer Frequency Range from 9 kHz to 3.2 GHz\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan class=\"fontstyle0\"\u003e-165 dBm\/Hz Displayed Average Noise Level (Typ.)\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan class=\"fontstyle0\"\u003e-98 dBc\/Hz.@10 kHz Offset Phase Noise (1 GHz, Typ.)\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan class=\"fontstyle0\"\u003eLevel Measurement Uncertainty \u0026lt; 0.7 dB (Typ.)\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan class=\"fontstyle0\"\u003e1 Hz Minimum Resolution Bandwidth (RBW)\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan class=\"fontstyle0\"\u003ePreamplifier and Tracking Generator Standard\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan class=\"fontstyle0\"\u003eVector Network Analyzer Mode Standard\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan class=\"fontstyle0\"\u003eDistance to Fault Mode Standard\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan class=\"fontstyle0\"\u003eUp to 40 MHz Real-Time Analysis Bandwidth\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan class=\"fontstyle0\"\u003e100% POI 7.20 μs, Dynamic Range 60 dB\u003c\/span\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\r\n\u003cthead\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eSSA3032X-R\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e9 kHz ~ 3.2 GHz\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eResolution Bandwidth\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e1 Hz ~ 3 MHz\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eDisplayed Average Noise Level\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e-165 dBm\/Hz\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eSSB Phase Noise\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u0026lt; -98 dBc\/Hz\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eThird-Order Intercept (TOI)\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e+14 dBm\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eTotal Amplitude Accuracy\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u0026lt; 0.7 dB\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eTracking Generator\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e100 kHz – 3.2 GHz\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eReal-Time Bandwidth\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e25 MHz, 40 MHz (Option)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eRTSA SFDR\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e60 dB\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003e100% POI\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e7.20 μs\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eRTSA Measurement\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eDensity, Spectrogram, 3D, PvT\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eVNA Measurement\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eVector S11, Vector S21\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eVNA Dynamic Range\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e90 dB\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eDistance to Fault\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eTiming Domain Analysis, Locator\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eMulti-touch, Mouse \u0026amp; Keyboard Supported\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eAdvanced Measurement\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eCHP, ACPR, OBW, CNR, Harmonic, TOI, Monitor\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eModulation Analysis\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eAM, FM, PM, ASK, FSK, MSK, PSK, QAM\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eEMI Measurement\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eEMI Filter, Quasi-Peak Detector, Log Scale, Limit Line\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eLAN, USB Device, USB Host (USB-GPIB)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eRemote Control Capability\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eSCPI \/ LabVIEW \/ IVI (USB-TMC, VXI-11, Socket, Telnet)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eRemote Controller\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eNI-MAX, Web Browser, Easy Spectrum Software, File Explorer\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\u003col\u003e\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D0747252702.pdf\"\u003eDatasheet - SSA3032X-R\u003c\/a\u003e\u003c\/li\u003e\u003c\/ol\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\" cellpadding=\"7\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eSpectrum Analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siglent","offers":[{"title":"Default Title","offer_id":53141243101484,"sku":"SSA3032X-R","price":77500.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0075\/8228\/5897\/files\/0b43b94fde3338fb52d39918f3ee6ef1.jpg?v=1777504495","url":"https:\/\/www.communica.co.za\/products\/ssa3032x-r","provider":"Communica South Africa","version":"1.0","type":"link"}