MGB-L2B-PNC-L-123012

SKU: MGB-L2B-PNC-L-123012

BRAND: Euchner


MGB LH Evaluation Module and Bus Module MGB-L2...-PN (Guard Locking by Solenoid Force) with 4 Control Elements, Push-Pull Plug

Evaluation Module and Bus Module

Feature(s)

  • Guard locking with guard lock monitoring
  • Emergency stop according to ISO 13850, illuminated
  • 3 illuminated pushbuttons
  • Push-pull plug
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
  • Multicode

Specifications

Electrical connection values

Connecting cable

 

Ethernet

Profinet I/O cable, at least cat. 5e

Rated insulation voltage Ui

75 V

Rated impulse voltage Uimp

0.5 kV

EMC protection requirements

In accordance with EN 61000-4 and EN 61326-3-1

maximum feed-in current in the connection block

 

X1, X2

max. 4000 mA

Safety class

III

Current consumption

max. 600 mA

Transponder coding

Multicode

Degree of contamination (external, according to EN 60947-1)

3

 

Power supply X1

Fuse

 

external

min. 1 A slow blow

Operating voltage DC

 

L1

24 V DC -15% ... +10% 

Auxiliary voltage DC

 

L2

24 V DC -15% ... +10% 

 

Power supply X2

Operating voltage DC

 

L1

24 V DC -15% ... +10% 

Auxiliary voltage DC

 

L2

24 V DC -15% ... +10% 

Mechanical values and environment

Connection type

 

 

Push-pull power 

for enabling switch

Plug connector RC12 

according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e

Push-pull RJ45 

 

Push-pull power 

according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e

Push-pull RJ45 

Installation orientation

Door hinge DIN left

Switching frequency

0.25 Hz

Mechanical life

 

 

1 x 10⁶

in case of use as door stop, and 1 Joule impact energy

0.1 x 10⁶

Response time

 

Enabling switch

max. 250 ms Turn-off time 

Bolt position

max. 550 ms Turn-off time 

Guard locking

max. 550 ms Turn-off time 

Emergency stop / machine stop

max. 250 ms Turn-off time 

Door position

max. 550 ms Turn-off time 

Shock and vibration resistance

Acc. to EN IEC 60947-5-3

Degree of protection

IP54

Ambient temperature

 

with UB = 24 V DC

-20 ... +55 °C

Material

 

Housing

Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Locking force FZh

2000 N

Guard locking principle

Open-circuit current principle

 