GW Instek AC 500VA AC/DC Withstanding Voltage/Insulation Resistance Tester
Withstanding Voltage/Insulation Resistance Tester
Features
500VA AC Test Capacity
Short Current > 200mA
240x64 Ice Blue Dot matrix LCD
Sweep Function for DUT characteristic analysis
Insulation resistance measurement up to 50GΩ(GPT-9903A/9904)
Manual/Auto Mode
Function Key for quick selection
High intensity flash for caution & Status indication
Safety INTERLOCK function
Zero Crossing Turn-on Operation
Controllable Ramp-up Time
RMS Current Measurement
High resolution: 1uA for measuring current, 2V for setting voltage
PWM amplifier to enhance the power efficiency and reliable testing
Max. 100 memory block for test condition (step) setting. And each step can be named individually.
Remote terminal on the front panel for “start” and “stop” control
Rear panel output available
Interface : RS-232C, USB device, Signal I/O and GPIB (optional)
Specifications
AC Withstanding Voltage
Output Voltage Range: 0.050 kV – 5.000 kV AC
Output Voltage Resolution: 2 V/step
Output Voltage Accuracy: ± (1% of setting + 5 V) [no load]
Maximum Rated Load: 500 VA (5 kV / 100 mA)
Maximum Rated Current:
100 mA (0.5 kV < V ≤ 5 kV)
10 mA (0.05 kV ≤ V ≤ 0.5 kV)
Output Voltage Waveform: Sine wave
Output Voltage Frequency: 50 Hz / 60 Hz selectable
Voltage Regulation: ± (1% of reading + 5 V) [full load to no load]
Voltmeter Accuracy: ± (1% of reading + 5 V)
Current Measurement Range: 0.001 mA – 100.0 mA
Current Best Resolution: 0.001 mA / 0.01 mA / 0.1 mA
AC Current Measurement Accuracy:
± (1.5% of reading + 30 counts) when HISET < 1.11 mA
± (1.5% of reading + 3 counts) when HISET ≥ 1.11 mA
Window Comparator Method: Yes
ARC Detection: Yes
Ramp-Up Time: 0.1 – 999.9 seconds
Test Timer: OFF / 0.5 – 999.9 seconds
Sweep Function: Yes
Ground (GND): ON/OFF
DC Withstanding Voltage
Output Voltage Range: 0.050 kV – 6.000 kV DC
Output Voltage Resolution: 2 V/step
Output Voltage Accuracy: ± (1% of setting + 5 V) [no load]
Maximum Rated Load: 100 W (5 kV / 20 mA)
Maximum Rated Current:
20 mA (0.5 kV < V ≤ 6 kV)
2 mA (0.05 kV ≤ V ≤ 0.5 kV)
Downloads
Additional Information
Elevate your testing capabilities with the GPT-9903A Insulation Resistance Tester. Designed for precision, it offers a 500VA AC test capacity, insulation resistance measurements up to 50GΩ, and a user-friendly interface. Experience reliable testing with advanced safety features and memory settings to optimize your workflow. Perfect for professionals seeking accuracy and efficiency in electrical testing.