Output Type: 2 Relay Outputs, 1 Transistor Output and 1 Current Output
Operating Frequency Range: 0.06 – 600,000 rpm
Power Supply: 24 VDC (verify exact supply range against datasheet)
Power Consumption: Less than 3 W (as specified)
Galvanic Isolation: Complete galvanic isolation
Monitoring Function: Over-speed and under-speed detection
Measurement Display: Integrated Digital Display
Data Logging: Ring Buffer for up to 8,000 Measured Values
Configuration: Front-Panel Buttons, PC (FDT/DTM) or HART
Input Protection: Reverse-Polarity Protected
Explosion Protection: ATEX and IECEx Certified
Hazardous Area Installation: Suitable for Zone 2
Protection Class: IP20
Housing Material: Polycarbonate / ABS
Dimensions (L × W × H): 104 × 27 × 110 mm
Ambient Temperature: -25°C to +70°C
Mounting: DIN-Rail Mounting
Application: Monitoring rotational speed, frequency and pulse signals in motors, gearboxes, turbines and industrial machinery.
Additional Information
Device
Monitor
Type
Rotation | speed | monitor
Enhance your industrial safety with the TURCK IM21-14EX-CDTRI Rotation Speed Monitor. This reliable, intrinsically safe isolating switch amplifier ensures accurate monitoring of rotational speed, protecting your machinery from over-speed and under-speed conditions. Featuring a digital display and data logging capabilities, it’s perfect for reliable performance in hazardous areas. Trust TURCK for precision and safety in your operations.