FLUKE T6-1000 PRO

SKU: FLUKE T6-1000 PRO

BRAND: Fluke


Electrical Tester 1000V AC/DC, Resolution:1V, Freq:45hz~66hz Through Open Fork, Resistance:1ω~100kω, AC Current:0.1~200A AC, True RMS, CatIII 1000V

1000V AC/DC Electrical Tester

Features

  • Save time by seeing voltage and current measurements at the same time
  • Visual Continuity™ – the screen automatically turns green for continuity, perfect when it’s too loud to hear the beeper
  • FieldSense™ technology for ac voltage, current and frequency, all without making electrical contact to live voltage

Specifications

Function
FieldSense ac voltage Requires test leads No
Range 1000 V
Resolution 1 V
Accuracy ±(3 % + 3 counts) 45 Hz - 66 Hz[1] [2]
FieldSense ac current Requires test leads No
Range 200.0 A
Resolution 0.1 A
Accuracy ±(3 % + 3 counts) 45 Hz - 66 Hz
FieldSense frequency (Hz) Requires test leads No
Range 45 Hz – 66 Hz
Resolution 1 Hz
Accuracy ±(1 % + 2 counts)
Volts ac Requires test leads Yes
Range 1000 V
Resolution 1 V
Accuracy ±(1.5 % + 2 counts) 45 Hz - 66 Hz
Volts dc Requires test leads Yes
Range 1000 V
Resolution 1 V
Accuracy ±(1 % + 2 counts)
Resistance Requires test leads (all ranges) Yes
Range 2000 Ω
Resolution 1 Ω
Range 20.00 kΩ
Resolution 0.01 kΩ
Range 100.0 kΩ
Resolution 0.1 kΩ
Accuracy (all ranges) ±(1 % + 2 counts)

Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC conversions are ac-coupled, RMS responding.

Accuracy[2]: FieldSense specified from 16V to 1000V.

General Specifications
Calibration 1-year calibration cycle
Dimensions 61 mm x 259 mm x 43 mm
Weight 0.35 kg (0.78 lb)
Fork opening 17.8 mm (0.7”)
Temperature
Operating:
Storage:

-10 °C to +50 °C (14 °F to 122 °F)
-30 °C to +60 °C (-22 °F to +140 °F)
Altitude
Operating:
Storage:

2,000 m (6,562 feet)
10,000 m (32,808 feet)
Relative Humidity 0 % to 90 %, 5 °C to 30 °C (41 °F to 86 °F)
0 % to 75 %, 30°C to 40 °C (86 °F to 104 °F)
0 % to 45 %, 40°C to 50 °C (104 °F to 122 °F)
Battery
Type:
Life:

2x AA (IEC LR6)
360 hour continuous, typical is 200 hour using the FieldSense function
Temperature coefficient 0.1 x (specified accuracy) / °C for <18°C or >28 °C (< 64.4 °F or > 82.4 °F)
Safety
General:
Measurement
T6-1000 PRO:

IEC 61010-1: Pollution Degree 2

IEC 61010-2-032: CAT IV 600 V / CAT III 1000 V
Electromagnetic Compatibility IEC/EN 61326-1: Portable

Downloads

Additional Information

Device Tester
Type Electrical | Tester

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)